BZLDK - UNDERCOAT SOUND DEADENER, 642

  • MSDS: BZLDK
  • Manufacturer: TERAND INDUSTRIES INC
  • Product Name: UNDERCOAT SOUND DEADENER, 642
  • National Stock Number: 8030-00N065283
Product Identification

Product ID:UNDERCOAT SOUND DEADENER, 642
MSDS Date:06/16/1994
FSC:8030
NIIN:00N065283
MSDS Number: BZLDK

Responsible Party
TERAND INDUSTRIES INC
FT LAUDERDALE, FL 33310
US

Emergency Phone: 800-255-3924

Info Phone: 305-974-5440

Cage: OO296

Contractor
TERAND INDUSTRIES, INC.
9947 FT. LAUNDERDALE, FL 33310

Telephone: 305-974-5440

Cage: OO296

Ingredients

MINERAL SPIRITS

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: 20-40%

OSHA PEL 400 PPM (MFR)

ACGIH TLV: 400 PPM (MFR)


OXYGENATED HYDROCARBON BLEND

Fraction By Weight: 20-40%

OSHA PEL N/K

ACGIH TLV: N/K


PETROLEUM GAS (LIQUEFIED); (LIQUEFIED PETROLEUM GAS)

CAS: 68476-85-7

RTECS: SE7545000

Fraction By Weight: 20-40%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE LIGHT IRRITATION
BUT DOES NOT INJURE EYE TISSUE. SKIN:FREQUENT OR PROLONGED CONTACT
MAY CAUSE IRRITATION. INHALATION:INHAL OF MIST CAN CAUSE IRRIT OF
NASAL & RESP PASSAGES. ABUSIV E/EXCESSIVE INHAL MAY CAUSE IRRIT TO
UPPER RESP TRACT, DIZZ, NAUS, & OTHER CNS EFTS. INGEST:CAN CAUSE
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:GI IRRIT, NAUS, VOMIT & DIARR. ASPIR
OF MATL INTO LUNGS CAN CAUSE CHEMICAL PNEUM. MINIMAL TOXICITY.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES:FLUSH W/LG AMTS OF COOL RUNNING WATER FOR @ LEAST 15
MINS WHILE HOLDING UPPER & LOWER LIDS OPEN. IF IRRIT PERSISTS GET
MED ATTN IMMED. SKIN:WASH W/SOAP & WATER. IF IRRIT PERSISTS SEEK
MED ATTN. I NHAL:REMOVE TO FRESH AIR. SEEK MED ATTNIMMED. IF BRTHG
STOPS GIVE ARTF RESP. INGEST:DO NOT INDUCE VOMIT. SEEK MED ATTN
IMMED.

Fire Fighting

Flash Point Method:TOC
Flash Point:48.0F,8.9C
Extinguishing Media:FOAM, CO*2, DRY MEDIA.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL FIRE EXPOSED CONTAINERS TO PREVENT RUPTURING.
Unusual Fire/Explosion Hazard:EXPOSURE TO TEMPERATURES ABOVE 120F MAY
CAUSE BURSTING.

Accidental Release

Spill Release Procedures:ALLOW PROPELLANT TO EVAP. MAINTAIN LOC EXHAUST
& ADEQ VENT. NO SMKNG. KEEP SPKS, HEAT SOURCES & OPEN FLAME FAR
AWAY FROM SPILL/LEAK. COVER W/ABSORB MATL & SWEEP UP. WASH AREA TO
PVNT SLIPPING. DISPOSE OF SOAKED ABSORB MATL I/A/W FED, STATE&
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP OUT OF REACH OF CHILDREN. FOR
INDUST & INSTITUTIONAL USE ONLY. STORE IN COOL, DRY AREA AWAY FROM
HEAT OR OPEN FLAME.
Other Precautions:DO NOT STORE AT TEMPERATURES ABOVE 120F. NFPA CODE
30B RATING:LEVEL 3 AEROSOL.

Exposure Controls

Respiratory Protection:NONE NEEDED FOR PROPER USE I/A/W LABEL
DIRECTIONS. NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:PROVIDE LOCAL EXHAUST TO KEEP TLV OF SECTION II INGREDIENTS
BELOW ACCEPTABLE LIMITS.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPEC GRAV:0.853 @ 75F (H*2O=1). SPILL RELEASE:LOCAL LAWS.

Chemical Properties

Boiling Pt:B.P. Text:248F,120C
Vapor Pres:55 @ 70F
Vapor Density:>1
Spec Gravity:SUPDAT
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SLIGHT
Appearance and Odor:BLACK LIQUID, SOLVENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON DIOXIDE, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:AEROSOL CANS, WHEN EMPTIED & DEPRESSURIZED
THROUGH NORMAL USE POSE NO DISP HAZ & SHOULD BE RECYCLED. CONSULT
FEDERAL, STATE AND LOCAL AUTH FOR APPROVED PROCEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.